Organic Rankine Cycle (ORC) units generate electricity from low- and medium-temperature waste heat: hot water 80–135 °C, low-pressure steam 1–7 barG or thermal oil. The working fluid circulates in a closed loop, so the system stays clean and needs little maintenance.
Screw-expander units cover 40–300 kW, turbine-expander units 300–1000 kW. Each system is designed for your heat source and cooling conditions to give the maximum annual power output. Economic service life is 20 years or more.

| Electric output | 40–1000 kW per unit |
| Heat source | Hot water 80–135 °C, steam 1–7 barG, thermal oil |
| Cooling water | 15–40 °C |
| Working fluid | R134a or R245fa |
| Expander | Semi-hermetic oil-injected twin-screw (40–300 kW) or semi-hermetic turbine (300–1000 kW) |
| Generator | Induction (asynchronous), 380 V / 3 ph / 50 Hz, 3000–3100 rpm, IP54 |
| Operating range | 20–110 % of rated output |
| Heat exchangers | Shell-and-tube flooded evaporator and condenser, 1.0 MPa water side |
| Controls | Modbus RTU, RS-485, cloud platform |
| Service life | ≥ 20 years |
Steel, cement, glass and ceramics plants; chemical, petrochemical and refinery waste heat; oil and gas field associated heat; biomass and gas engine jacket water; geothermal and solar thermal sources; food, paper and textile process heat.
| Model | Dimensions L × W × H, mm | Weight, kg | Output, R134a, hot water 95 °C, kW | Output, R245fa, hot water 130 °C, kW | Output, R245fa, steam 2 barG, kW | Power range, kW |
|---|---|---|---|---|---|---|
| ORC-S40 | 2200 × 1500 × 1800 | 3 000 | 49 | 54 | 44 | 10–60 |
| ORC-S80 | 2500 × 1800 × 2000 | 5 000 | 79 | 76 | 79 | 15–90 |
| ORC-S160 | 4000 × 2500 × 3000 | 10 000 | 159 | 157 | 160 | 40–200 |
| ORC-S300 | 6000 × 2800 × 3500 | 15 000 | 298 | 279 | 295 | 60–320 |
Typical ranges. Final selection and parameters are confirmed in the quotation for your project.
| Model | Dimensions L × W × H, mm | Weight, kg | Output, hot water 120 °C, kW | Hot water flow, m³/h | Power range, kW |
|---|---|---|---|---|---|
| ORC-T700 | 7000 × 4000 × 6000 | 65 000 | 648 | 200 | 120–700 |
| ORC-T1000 | 8000 × 4500 × 6800 | 90 000 | 964 | 300 | 200–1000 |
Typical ranges. Final selection and parameters are confirmed in the quotation for your project.



Hot water from about 80 °C (R134a units 80–95 °C, R245fa units 100–135 °C) or saturated steam at 1–7 barG. Thermal oil can also be used.
It depends on heat-source flow and temperature and on cooling water temperature. For example, 40 m³/h of 95 °C water gives about 79 kW. Send us your data for a calculation.
Yes. The induction generator delivers 380 V / 50 Hz power to the grid through a grid-connection cabinet with full protection.
Very little: the closed loop keeps the working fluid clean and the semi-hermetic expander has no external shaft seal. The cloud platform allows remote diagnostics.






Tell us the duty, medium and site conditions. We will reply with a technical and commercial offer.