Lithium bromide absorption chillers

Absorption chillers turn steam, hot water, exhaust gas or fuel into chilled water, using waste heat instead of electricity. They are a proven choice for refineries, chemical plants, CCHP plants, data centres and large buildings.

We supply steam (single and double effect), hot-water, direct-fired and flue-gas units with capacity up to about 7,000 kW per unit, helium leak tested, with touch-screen control and BMS connection.

Steam-operated absorption chiller

Key specifications

TypesSteam, hot water, direct-fired (gas / oil), flue gas / exhaust heat
Cooling capacityUp to approx. 7,000 kW per unit (2,000 USRT)
EfficiencyCOP up to 1.55 (steam, double effect)
Heat sourceSteam 0.4 – 0.8 MPa(g); hot water ≥ 90 °C; flue gas ≥ 250 °C
OperationChilled water down to 5 °C; capacity control 20 – 100 %
CertificatesAgreed in the quotation and contract

Features

  • Helium leak-tested vacuum tightness for stable capacity
  • Touch-screen control with BMS link (RS232 / 422 / 485) and remote monitoring
  • Capacity control 20 – 100 %, chilled / hot water flow 60 – 120 %
  • Anti-crystallization control and automatic purge system
  • Cooling and heating in one unit (direct-fired and flue gas types)

Applications

Trigeneration (CCHP), waste-heat recovery in refineries and chemical plants, industrial process cooling, data centers, hotels and commercial buildings, district cooling.

Model range

TypeHeat sourceRange / efficiencyTypical use
Steam, double effectSteam 0.4 – 0.8 MPa(g)COP 1.43 – 1.55Plants with process or boiler steam
Steam, single effectLow-pressure / waste steamOn requestRecovery of exhaust and waste steam
Hot water (single / two stage)Hot water, incl. waste-heat waterOn requestWaste-heat recovery, district heating networks
Direct-fired chiller / heaterNatural gas, LPG, city gas, light / heavy oilCOP 1.25 – 1.42Cooling and heating without a steam supply
Flue gas / exhaust heatFlue gas ≥ 250 °C, engine jacket water66 – 2,000 USRTTrigeneration (CCHP) with gas turbines and engines

Typical ranges. Final selection and parameters are confirmed in the quotation for your project.

Photos

Steam-operated absorption chiller
Steam-operated absorption chiller
Flue gas absorption chiller
Flue gas absorption chiller

Process diagrams

Steam-operated double-effect absorption chiller — cooling cycle
Steam-operated double-effect absorption chiller — cooling cycle
Steam circuit, high / low pressure generators, heat exchangers, absorber, evaporator and condenser
Flue gas absorption chiller — cooling cycle
Flue gas absorption chiller — cooling cycle
Flue gas inlet / outlet, generators, solution and refrigerant circuits, chilled and cooling water

Why CHEMGASOIL

Quality assuranceProducts to agreed specifications and standards
Global sourcingReliable supply chains across Asia and beyond
Engineering expertiseMaintenance and technical service on site
Full documentationQuotations, invoices and contracts in order

Frequently asked questions

Which heat sources can drive the chiller?

Steam 0.4–0.8 MPa g, hot water from about 90 °C (including waste water), flue gas from 250 °C, engine jacket water, natural gas, LPG or oil.

What efficiency can I expect?

COP up to 1.55 for double-effect steam units and 1.25–1.42 for direct-fired units, depending on design conditions.

Can one unit provide both cooling and heating?

Yes. Direct-fired and flue-gas units can supply chilled water in summer and hot water in winter.

What documents do I receive?

Process diagrams, dimensional drawings and a full technical datasheet with the quotation; certificates are agreed in the quotation and contract.

Other equipment

Send us your requirements

Tell us the duty, medium and site conditions. We will reply with a technical and commercial offer.